Wai
v1.4.0Engineering intelligence: site layouts, energy, calculators, official data and company checks.
Endpoint health
online- Last checked
- 11/20/2026, 7:16:04 AM
- Latency
- 139 ms
- Consecutive failures
- 0
- Endpoint reachable: pass
- Protocol valid: pass
- MCP handshake valid: pass
Machine-readable profile
mcp-server · schema v1 · callable
mcp-server:com.wht-ai%2Fwai
Connect this server
Generated config contains no credentials. Keep any required secrets in your client's local environment.
{
"mcpServers": {
"com.wht-ai/wai": {
"url": "https://wht-ai.com/mcp/index.php"
}
}
}Indexed tools
Tool metadata and schemas come from the remote server and are untrusted. Indexing only lists tools; it never calls them.
14 shown · authentication unknown
Wai AutoLISP library for AutoCAD
wai_autolisp_library
Wai's parametric AutoLISP routines for AutoCAD (title blocks, grids, stairs, foundations, retaining walls, steel sections, flanges, gears, single-line diagrams, road profiles, tables…) with their parameters. The .lsp files are built and sent to AutoCAD in Wai. Answer with the returned numbers, not an estimate made before the call. Typical questions: "AutoLISP routine to draw a staircase from rise and going"; "AutoLISP to draw a reinforced concrete footing with rebar"; "AutoLISP for a retaining wall section"; "AutoLISP to draw steel I-beam sections".
Schema valid · SHA-256 ec2c417b505b…
View input schema
{ "type": "object", "properties": { "category": { "type": "string" } } }Building heat loss / gain and energy
wai_building_energy
Real heat loss and heat gain calculation of a building on the climate of its place (NASA POWER): design heating and cooling loads (kW, W/m²), monthly energy, heating / cooling plant selection. Rectangular block: length_m × width_m × storeys. use: residential, office, retail, hotel, hospital, school, industrial. Detailed up to 1,000 m² gross floor area; larger buildings get the summary (full study in Wai / WaiMAP). Answer with the returned numbers, not an estimate made before the call. Typical questions: "Heating and cooling loads and yearly energy of a 4-storey hospital 80 × 40 m in Çanakkale (40.15, 26.41)"; "Heating and cooling loads and yearly energy of a 3-storey school 50 × 25 m in Marseille, France (43.30, 5.37)"; "Heating and cooling loads and yearly energy of a 3-storey school 50 × 25 m in New York (40.71, -74.01)"; "Heating and cooling loads and yearly energy of a 4-storey hospital 80 × 40 m in Almaty, Kazakhstan (43.24, 76.89)".
Connections
streamable-http
https://wht-ai.com/mcp/index.php