Heat exchanger fouling resistance back-calculation from shell/tube-side operating conditions using Delaware + Gnielinski.
View input schema
{
"type": "object",
"properties": {
"Unknown": {
"type": "string",
"description": "Which unknown is being solved for.",
"enum": [
"tube-V",
"tube-T2",
"shll-V",
"shll-T2"
]
},
"D_shll": {
"type": "object",
"description": "Shell inside diameter",
"properties": {
"value": {
"type": "number"
},
"unit": {
"type": "string",
"enum": [
"cm",
"ft",
"in",
"m",
"micron",
"miles",
"mm"
]
}
},
"required": [
"value",
"unit"
]
},
"D_tube": {
"type": "object",
"description": "Tube outside diameter",
"properties": {
"value": {
"type": "number"
},
"unit": {
"type": "string",
"enum": [
"cm",
"ft",
"in",
"m",
"micron",
"miles",
"mm"
]
}
},
"required": [
"value",
"unit"
]
},
"D_wall": {
"type": "object",
"description": "Tube wall thickness",
"properties": {
"value": {
"type": "number"
},
"unit": {
"type": "string",
"enum": [
"cm",
"ft",
"in",
"m",
"micron",
"miles",
"mm"
]
}
},
"required": [
"value",
"unit"
]
},
"P_tube": {
"type": "object",
"description": "Tube pitch",
"properties": {
"value": {
"type": "number"
},
"unit": {
"type": "string",
"enum": [
"cm",
"ft",
"in",
"m",
"micron",
"miles",
"mm"
]
}
},
"required": [
"value",
"unit"
]
},
"LP_tube": {
"type": "string",
"description": "Layout pattern of tube in shell",
"enum": [
"square",
"rotated_square",
"triangular"
]
},
"S_baffle": {
"type": "object",
"description": "Baffle spacing",
"properties": {
"value": {
"type": "number"
},
"unit": {
"type": "string",
"enum": [
"cm",
"ft",
"in",
"m",
"micron",
"miles",
"mm"
]
}
},
"required": [
"value",
"unit"
]
},
"C_baffle": {
"type": "object",
"description": "Baffle cut as a fraction of shell diameter, 0 < value <= 0.5",
"properties": {
"value": {
"type": "number"
},
"unit": {
"type": "string",
"enum": [
""
]
}
},
"required": [
"value"
]
},
"N_tube": {
"type": "object",
"description": "Number of tubes",
"properties": {
"value": {
"type": "number"
},
"unit": {
"type": "string",
"enum": [
"EA",
"ea"
]
}
},
"required": [
"value",
"unit"
]
},
"L_tube": {
"type": "object",
"description": "Tube length",
"properties": {
"value": {
"type": "number"
},
"unit": {
"type": "string",
"enum": [
"cm",
"ft",
"in",
"m",
"micron",
"miles",
"mm"
]
}
},
"required": [
"value",
"unit"
]
},
"N_shllseri": {
"type": "object",
"description": "Number of shells in series",
"properties": {
"value": {
"type": "number"
},
"unit": {
"type": "string",
"enum": [
"EA",
"ea"
]
}
},
"required": [
"value",
"unit"
]
},
"N_shllpara": {
"type": "object",
"description": "Number of shells in parallel",
"properties": {
"value": {
"type": "number"
},
"unit": {
"type": "string",
"enum": [
"EA",
"ea"
]
}
},
"required": [
"value",
"unit"
]
},
"N_shllpass": {
"type": "object",
"description": "Number of shell-side passes",
"properties": {
"value": {
"type": "number"
},
"unit": {
"type": "string",
"enum": [
"EA",
"ea"
]
}
},
"required": [
"value",
"unit"
]
},
"N_tubepass": {
"type": "object",
"description": "Number of tube-side passes",
"properties": {
"value": {
"type": "number"
},
"unit": {
"type": "string",
"enum": [
"EA",
"ea"
]
}
},
"required": [
"value",
"unit"
]
},
"A_hex": {
"type": "object",
"description": "Total heat transfer area",
"properties": {
"value": {
"type": "number"
},
"unit": {
"type": "string",
"enum": [
"cm2",
"ft2",
"in2",
"m2"
]
}
},
"required": [
"value",
"unit"
]
},
"R_shll": {
"type": "object",
"description": "Shell-side fouling resistance",
"properties": {
"value": {
"type": "number"
},
"unit": {
"type": "string",
"enum": [
"C-h-m2/J",
"C-h-m2/kJ",
"C-h-m2/kcal",
"C-m2/W",
"C-m2/kW",
"F-hr-ft2/Btu",
"hr-ft2-F/Btu"
]
}
},
"required": [
"value",
"unit"
]
},
"R_tube": {
"type": "object",
"description": "Tube-side fouling resistance",
"properties": {
"value": {
"type": "number"
},
"unit": {
"type": "string",
"enum": [
"C-h-m2/J",
"C-h-m2/kJ",
"C-h-m2/kcal",
"C-m2/W",
"C-m2/kW",
"F-hr-ft2/Btu",
"hr-ft2-F/Btu"
]
}
},
"required": [
"value",
"unit"
]
},
"F": {
"type": "object",
"description": "Correction factor (dimensionless)",
"properties": {
"value": {
"type": "number"
},
"unit": {
"type": "string",
"enum": [
""
]
}
},
"required": [
"value"
]
},
"k_hex": {
"type": "object",
"description": "Tube wall thermal conductivity",
"properties": {
"value": {
"type": "number"
},
"unit": {
"type": "string",
"enum": [
"Btu/hr-ft-F",
"Btu/hr-ft-R",
"Kcal/m-hr-C",
"Kcal/m-hr-K",
"W/m-C",
"W/m-K"
]
}
},
"required": [
"value",
"unit"
]
},
"T_shll": {
"type": "object",
"description": "Shell-side fluid temperature range",
"properties": {
"value": {
"type": "array",
"items": {
"type": "number"
}
},
"unit": {
"type": "string",
"enum": [
"C",
"F",
"K",
"R"
]
}
},
"required": [
"value",
"unit"
]
},
"rho_shll": {
"type": "object",
"description": "Shell-side fluid density list",
"properties": {
"value": {
"type": "array",
"items": {
"type": "number"
}
},
"unit": {
"type": "string",
"enum": [
"API",
"SG_H2O4",
"SG_H2O60api",
"SG_H2O60nbs",
"g/cm3",
"g/cm^3",
"kg/m3",
"kg/m^3",
"lb/ft3",
"lb/ft^3",
"lbm/ft^3"
]
}
},
"required": [
"value",
"unit"
]
},
"Cp_shll": {
"type": "object",
"description": "Shell-side fluid heat capacity list",
"properties": {
"value": {
"type": "array",
"items": {
"type": "number"
}
},
"unit": {
"type": "string",
"enum": [
"Btu/lb-F",
"Btu/lb-R",
"Btu/lbm-F",
"Btu/lbm-R",
"J/g-C",
"J/g-K",
"J/kg-C",
"J/kg-K",
"cal/g-C",
"cal/g-K",
"cal/kg-C",
"cal/kg-K",
"kJ/g-C",
"kJ/g-K",
"kJ/kg-C",
"kJ/kg-K",
"kcal/g-C",
"kcal/g-K",
"kcal/kg-C",
"kcal/kg-K"
]
}
},
"required": [
"value",
"unit"
]
},
"mu_shll": {
"type": "object",
"description": "Shell-side fluid viscosity list",
"properties": {
"value": {
"type": "array",
"items": {
"type": "number"
}
},
"unit": {
"type": "string",
"enum": [
"P",
"Pa-s",
"cP",
"lb/ft-sec",
"lb/h-ft",
"lbf-s/ft2",
"lbm/h-ft",
"lbm/s-ft",
"mP",
"microP",
"poundals/ft2",
"slug/h-ft"
]
}
},
"required": [
"value",
"unit"
]
},
"k_shll": {
"type": "object",
"description": "Shell-side fluid thermal conductivity list",
"properties": {
"value": {
"type": "array",
"items": {
"type": "number"
}
},
"unit": {
"type": "string",
"enum": [
"Btu/hr-ft-F",
"Btu/hr-ft-R",
"Kcal/m-hr-C",
"Kcal/m-hr-K",
"W/m-C",
"W/m-K"
]
}
},
"required": [
"value",
"unit"
]
},
"T_tube": {
"type": "object",
"description": "Tube-side fluid temperature range",
"properties": {
"value": {
"type": "array",
"items": {
"type": "number"
}
},
"unit": {
"type": "string",
"enum": [
"C",
"F",
"K",
"R"
]
}
},
"required": [
"value",
"unit"
]
},
"rho_tube": {
"type": "object",
"description": "Tube-side fluid density list",
"properties": {
"value": {
"type": "array",
"items": {
"type": "number"
}
},
"unit": {
"type": "string",
"enum": [
"API",
"SG_H2O4",
"SG_H2O60api",
"SG_H2O60nbs",
"g/cm3",
"g/cm^3",
"kg/m3",
"kg/m^3",
"lb/ft3",
"lb/ft^3",
"lbm/ft^3"
]
}
},
"required": [
"value",
"unit"
]
},
"Cp_tube": {
"type": "object",
"description": "Tube-side fluid heat capacity list",
"properties": {
"value": {
"type": "array",
"items": {
"type": "number"
}
},
"unit": {
"type": "string",
"enum": [
"Btu/lb-F",
"Btu/lb-R",
"Btu/lbm-F",
"Btu/lbm-R",
"J/g-C",
"J/g-K",
"J/kg-C",
"J/kg-K",
"cal/g-C",
"cal/g-K",
"cal/kg-C",
"cal/kg-K",
"kJ/g-C",
"kJ/g-K",
"kJ/kg-C",
"kJ/kg-K",
"kcal/g-C",
"kcal/g-K",
"kcal/kg-C",
"kcal/kg-K"
]
}
},
"required": [
"value",
"unit"
]
},
"mu_tube": {
"type": "object",
"description": "Tube-side fluid viscosity list",
"properties": {
"value": {
"type": "array",
"items": {
"type": "number"
}
},
"unit": {
"type": "string",
"enum": [
"P",
"Pa-s",
"cP",
"lb/ft-sec",
"lb/h-ft",
"lbf-s/ft2",
"lbm/h-ft",
"lbm/s-ft",
"mP",
"microP",
"poundals/ft2",
"slug/h-ft"
]
}
},
"required": [
"value",
"unit"
]
},
"k_tube": {
"type": "object",
"description": "Tube-side fluid thermal conductivity list",
"properties": {
"value": {
"type": "array",
"items": {
"type": "number"
}
},
"unit": {
"type": "string",
"enum": [
"Btu/hr-ft-F",
"Btu/hr-ft-R",
"Kcal/m-hr-C",
"Kcal/m-hr-K",
"W/m-C",
"W/m-K"
]
}
},
"required": [
"value",
"unit"
]
},
"V_shll": {
"type": "object",
"description": "Shell-side volumetric flow rate",
"properties": {
"value": {
"type": "number"
},
"unit": {
"type": "string",
"enum": [
"L/day",
"L/hr",
"L/min",
"L/sec",
"USGPH",
"USGPM",
"barrel/day",
"barrel/hr",
"ft3/day",
"ft3/hr",
"gph",
"gpm",
"m3/day",
"m3/hr",
"m3/min",
"m3/sec"
]
}
},
"required": [
"value",
"unit"
]
},
"T1_shll": {
"type": "object",
"description": "Shell-side inlet temperature",
"properties": {
"value": {
"type": "number"
},
"unit": {
"type": "string",
"enum": [
"C",
"F",
"K",
"R"
]
}
},
"required": [
"value",
"unit"
]
},
"T2_shll": {
"type": "object",
"description": "Shell-side outlet temperature",
"properties": {
"value": {
"type": "number"
},
"unit": {
"type": "string",
"enum": [
"C",
"F",
"K",
"R"
]
}
},
"required": [
"value",
"unit"
]
},
"V_tube": {
"type": "object",
"description": "Tube-side volumetric flow rate",
"properties": {
"value": {
"type": "number"
},
"unit": {
"type": "string",
"enum": [
"L/day",
"L/hr",
"L/min",
"L/sec",
"USGPH",
"USGPM",
"barrel/day",
"barrel/hr",
"ft3/day",
"ft3/hr",
"gph",
"gpm",
"m3/day",
"m3/hr",
"m3/min",
"m3/sec"
]
}
},
"required": [
"value",
"unit"
]
},
"T1_tube": {
"type": "object",
"description": "Tube-side inlet temperature",
"properties": {
"value": {
"type": "number"
},
"unit": {
"type": "string",
"enum": [
"C",
"F",
"K",
"R"
]
}
},
"required": [
"value",
"unit"
]
},
"T2_tube": {
"type": "object",
"description": "Tube-side outlet temperature",
"properties": {
"value": {
"type": "number"
},
"unit": {
"type": "string",
"enum": [
"C",
"F",
"K",
"R"
]
}
},
"required": [
"value",
"unit"
]
},
"u_shll_unit": {
"type": "string",
"description": "Output shell-side velocity unit",
"enum": [
"MPH",
"cm/sec",
"ft/hr",
"ft/min",
"ft/sec",
"km/hr",
"m/hr",
"m/min",
"m/s",
"m/sec"
],
"default": "ft/sec"
},
"u_tube_unit": {
"type": "string",
"description": "Output tube-side velocity unit",
"enum": [
"MPH",
"cm/sec",
"ft/hr",
"ft/min",
"ft/sec",
"km/hr",
"m/hr",
"m/min",
"m/s",
"m/sec"
],
"default": "ft/sec"
},
"h_shll_unit": {
"type": "string",
"description": "Output shell-side film heat transfer coefficient unit",
"enum": [
"Btu/hr-ft2-F",
"W/m2-C",
"kJ/h-m2-C",
"kJ/s-m2-C",
"kcal/h-m2-C"
],
"default": "Btu/hr-ft2-F"
},
"h_tube_unit": {
"type": "string",
"description": "Output tube-side film heat transfer coefficient unit",
"enum": [
"Btu/hr-ft2-F",
"W/m2-C",
"kJ/h-m2-C",
"kJ/s-m2-C",
"kcal/h-m2-C"
],
"default": "Btu/hr-ft2-F"
},
"U_cln_unit": {
"type": "string",
"description": "Output clean overall heat transfer coefficient unit",
"enum": [
"Btu/hr-ft2-F",
"W/m2-C",
"kJ/h-m2-C",
"kJ/s-m2-C",
"kcal/h-m2-C"
],
"default": "Btu/hr-ft2-F"
},
"U_act_unit": {
"type": "string",
"description": "Output actual (fouled) overall heat transfer coefficient unit",
"enum": [
"Btu/hr-ft2-F",
"W/m2-C",
"kJ/h-m2-C",
"kJ/s-m2-C",
"kcal/h-m2-C"
],
"default": "Btu/hr-ft2-F"
},
"Q_unit": {
"type": "string",
"description": "Output heat duty unit",
"enum": [
"Btu/hr",
"Gcal/hr",
"MBtu/hr",
"MW",
"Mcal/hr",
"W",
"cal/hr",
"hp",
"kBtu/hr",
"kW",
"kcal/hr"
],
"default": "MBtu/hr"
},
"Rf_unit": {
"type": "string",
"description": "Output fouling resistance unit",
"enum": [
"C-h-m2/J",
"C-h-m2/kJ",
"C-h-m2/kcal",
"C-m2/W",
"C-m2/kW",
"F-hr-ft2/Btu",
"hr-ft2-F/Btu"
],
"default": "hr-ft2-F/Btu"
}
},
"required": [
"Unknown",
"D_shll",
"D_tube",
"D_wall",
"P_tube",
"LP_tube",
"S_baffle",
"C_baffle",
"N_tube",
"L_tube",
"N_shllseri",
"N_shllpara",
"N_shllpass",
"N_tubepass",
"A_hex",
"R_shll",
"R_tube",
"F",
"k_hex",
"T_shll",
"rho_shll",
"Cp_shll",
"mu_shll",
"k_shll",
"T_tube",
"rho_tube",
"Cp_tube",
"mu_tube",
"k_tube",
"V_shll",
"T1_shll",
"T2_shll",
"V_tube",
"T1_tube",
"T2_tube"
]
}