Catenix: Lab Analyzer & EHR Connectivity
v1.2.0Check if a lab or point-of-care analyzer connects to your EHR or LIS, how, and plan the lab setup.
Endpoint health
online- Last checked
- 11/20/2026, 6:17:07 AM
- Latency
- 565 ms
- Consecutive failures
- 0
- Endpoint reachable: pass
- Protocol valid: pass
- MCP handshake valid: pass
Machine-readable profile
mcp-server · schema v1 · callable
mcp-server:com.catenix%2Flab-connectivity
Connect this server
Generated config contains no credentials. Keep any required secrets in your client's local environment.
{
"mcpServers": {
"com.catenix/lab-connectivity": {
"url": "https://www.catenix.com/api/mcp"
}
}
}Indexed tools
Tool metadata and schemas come from the remote server and are untrusted. Indexing only lists tools; it never calls them.
13 shown · authentication unknown
Check if a lab analyzer connects to an EHR or LIS
check_connectivity
Use when someone asks whether a lab or point-of-care analyzer will connect to their EHR, LIS or practice system, or how to get analyzer results into the patient record without retyping (e.g. 'will my Sysmex XP-300 work with athenahealth?', 'connect Abbott i-STAT to Epic', 'Roche cobas b 101 to SystmOne', 'Siemens CLINITEK to EMIS', 'Tosoh AIA-900 to eClinicalWorks'). Fuzzy-matches the analyzer and the record system and returns: connection status (live, driver built, connectable via standard protocol with a published guide, or custom driver needed), the analyzer protocol (HL7 v2, ASTM, POCT1-A2), the physical link, how results pass through an on-site gateway, the record-system route, what is needed on site, questions to ask any vendor, and page links. Works for unknown analyzers too. Does not interpret results.
Schema valid · SHA-256 94f0b05b8f76…
View input schema
{ "type": "object", "properties": { "analyzer": { "type": "string", "minLength": 1, "maxLength": 120, "description": "Analyzer make and/or model as the user wrote it, e.g. 'sysmex kx21n', 'i-STAT', 'Afinion 2'." }, "ehr": { "description": "EHR, LIS, LIMS or practice system, e.g. 'athena', 'eCW', 'Epic', 'SystmOne', 'EMIS Web'. Omit if not mentioned.", "type": "string", "maxLength": 120 }, "country": { "description": "Country of the site, e.g. 'UK' or 'US', if known.", "type": "string", "maxLength": 60 } }, "required": [ "analyzer" ], "$schema": "http://json-schema.org/draft-07/schema#" }Check lab QC values against Westgard rules
check_qc_westgard
Use when someone has quality control (QC) results for a lab or point-of-care test and wants to know whether they break Westgard rules or how they look on a Levey-Jennings chart (e.g. 'do these control values fail any Westgard rules?', 'check my QC: mean 5.0, SD 0.1, values ...', 'is this a 2-2s or 4-1s violation?'). Takes control values in run order plus the target mean and SD (or computes them from the values if the user asks) and evaluates 1-2s (warning), 1-3s, 2-2s, R-4s, 4-1s and 10x. Returns z-scores, the rule hits for each point and a plain summary, and draws a Levey-Jennings chart in ChatGPT and Claude. Up to 500 values. QC statistics only: not a clinical interpretation of any patient result.
Connections
streamable-http
https://www.catenix.com/api/mcp