Andare Homes Tools
v1.0.0Planning calculators for custom homes, additions and major renovations.
Endpoint health
online- Last checked
- 11/20/2026, 6:18:40 AM
- Latency
- 122 ms
- Consecutive failures
- 0
- Endpoint reachable: pass
- Protocol valid: pass
- MCP handshake valid: pass
Machine-readable profile
mcp-server · schema v1 · callable
mcp-server:com.andarehomes%2Ftools
Connect this server
Generated config contains no credentials. Keep any required secrets in your client's local environment.
{
"mcpServers": {
"com.andarehomes/tools": {
"url": "https://andarehomes.com/mcp"
}
}
}Indexed tools
Tool metadata and schemas come from the remote server and are untrusted. Indexing only lists tools; it never calls them.
11 shown · authentication unknown
Accessible ramp and doorway calculator
accessible-ramp-and-doorway-calculator
Ramp length for a rise at the Ontario Building Code 1 in 12 gradient, a slope check, or a doorway clear width check, using Section 3.8. Preliminary planning only. Example: /api/tools/accessible-ramp-and-doorway-calculator?mode=len&units=mm&rise=600
Schema valid · SHA-256 ac36ada67622…
View input schema
{ "type": "object", "properties": { "mode": { "description": "len = ramp length needed for a rise (needs rise); slope = check an existing slope (needs rise and run); door = doorway clear width (needs width and door)", "type": "string", "enum": [ "len", "slope", "door" ] }, "units": { "description": "Units of rise, run and width", "type": "string", "enum": [ "mm", "in" ] }, "rise": { "description": "Total rise (modes len and slope) (units)", "type": "number" }, "run": { "description": "Horizontal run (mode slope) (units)", "type": "number" }, "width": { "description": "Clear width with the door open (mode door) (units)", "type": "number" }, "door": { "description": "Which doorway (mode door): path = barrier-free path of travel; suite-wide = bathroom or bedroom door in a suite served by a corridor 1,060 mm or wider; suite-narrow = same, corridor narrower than 1,060 mm", "type": "string", "enum": [ "path", "suite-wide", "suite-narrow" ] } }, "required": [ "mode" ] }Basement ceiling height and egress checker
basement-ceiling-height-and-egress-checker
Tests basement ceiling height, height under beams and ducts, and stair headroom against Ontario Building Code Part 9, for a house basement or a secondary suite. Window sizes are tested by the egress window size calculator. Preliminary planning only. Example: /api/tools/basement-ceiling-height-and-egress-checker?units=mm&type=suite&ceiling=2000&obstruction=1900&stair=1980
Connections
streamable-http
https://andarehomes.com/mcp