ivive.app
v1.0.3Human hepatic clearance from in-vitro CLint, with the error band measured on known drugs.
Endpoint health
online- Last checked
- 11/3/2026, 7:17:56 PM
- Latency
- 309 ms
- Consecutive failures
- 0
- Endpoint reachable: pass
- Protocol valid: pass
- MCP handshake valid: pass
Machine-readable profile
mcp-server · schema v1 · callable
mcp-server:app.ivive%2Fivive
Connect this server
Generated config contains no credentials. Keep any required secrets in your client's local environment.
{
"mcpServers": {
"app.ivive/ivive": {
"url": "https://api.ivive.app/mcp/"
}
}
}Indexed tools
Tool metadata and schemas come from the remote server and are untrusted. Indexing only lists tools; it never calls them.
6 shown · authentication unknown
calc_clhep
Hepatic and plasma clearance from in-vitro CLint, fu,mic and fu,p (IVIVE), with the observed-CL band and applicability warnings. If fu,p or fu,mic came from predict_inputs, tell the user the result rests on predicted inputs.
Schema valid · SHA-256 7293d203ca61…
View input schema
{ "type": "object", "properties": { "clint": { "description": "Intrinsic clearance (µL/min/mg microsomal protein). Use ge=0: zero clearance is physiologically valid.", "minimum": 0, "title": "Clint", "type": "number" }, "fu_mic": { "description": "Unbound fraction in microsomes (0–1). Corrects for non-specific microsomal binding.", "exclusiveMinimum": 0, "maximum": 1, "title": "Fu Mic", "type": "number" }, "fu_p": { "description": "Unbound fraction in plasma (0–1). Plasma protein binding correction.", "maximum": 1, "minimum": 0, "title": "Fu P", "type": "number" }, "rb": { "default": 1, "description": "Blood-to-plasma concentration ratio. fu_b = fu_p / Rb. Output is blood clearance.", "exclusiveMinimum": 0, "maximum": 50, "title": "Rb", "type": "number" }, "species": { "description": "Species for physiological parameters (Qh, MPPGL, liver weight).", "enum": [ "human", "rat", "dog" ], "title": "Species", "type": "string" }, "model": { "default": "well-stirred", "description": "IVIVE model. well-stirred (venous equilibrium) or parallel-tube (sinusoidal perfusion).", "enum": [ "well-stirred", "parallel-tube" ], "title": "Model", "type": "string" }, "assay_type": { "default": "microsomes", "description": "Assay type for CLint scaling. microsomes: uses MPPGL (mg/g) × 1e-3; hepatocytes: uses HPGL (×10⁶ cells/g) × 1e-3.", "enum": [ "microsomes", "hepatocytes" ], "title": "Assay Type", "type": "string" }, "correction_id": { "anyOf": [ { "format": "uuid", "type": "string" }, { "type": "null" } ], "default": null, "description": "Saved lab correction (/api/correction-equations) to apply. Must match species and assay_type. Corrects predicted plasma CL and replaces the reference band with one from the lab's compounds.", "title": "Correction Id" }, "clint_censored": { "default": false, "description": "Set when the assay reported CLint below its limit of quantification and `clint` is that limit rather than a measurement. CLint then lies in [0, clint), so every clearance output is an upper bound: `upper_bound` is true, no observed-CL band is returned, and the clint_below_loq flag fires.", "title": "Clint Censored", "type": "boolean" } }, "required": [ "clint", "fu_mic", "fu_p", "species" ], "title": "CLhepRequest" }
Connections
streamable-http
https://api.ivive.app/mcp/