{"data":{"name":"com.thegrateguys/tools","title":"The Grate Guys Tools","description":"Planning calculators for metal grating, drainage covers and fabrication.","version":"1.0.0","websiteUrl":null,"repositoryUrl":null,"remotes":[{"type":"streamable-http","url":"https://thegrateguys.com/mcp"}],"packages":[],"status":"active","isLatest":true,"publishedAt":"2026-11-16T21:56:17.668Z","updatedAt":"2026-11-16T21:56:17.668Z","source":"official-registry","verification":"official","confidence":100,"stars":null,"sources":[{"source":"official-registry","sourceId":"com.thegrateguys/tools","verification":"official","confidence":100,"stars":null,"updatedAt":"2026-11-16T21:56:17.668Z","title":"The Grate Guys Tools","description":"Planning calculators for metal grating, drainage covers and fabrication.","websiteUrl":null,"repositoryUrl":null}],"toolIndex":{"tools":[{"serverName":"com.thegrateguys/tools","endpointFingerprint":"eb460a635fcdd156e1f4e8aec173cf12565637c41c2e46bc8c82b6e6668edd02","name":"accessible_grating_opening_checker","title":null,"description":"Checks the clear opening between bearing bars against the Ontario Building Code 13 mm limit for barrier-free paths of travel, and the widest bar spacing that would pass.","inputSchema":{"type":"object","properties":{"pattern":{"type":"string","description":"19-W-4 (1-3/16 in centres), 15-W-4 (15/16 in centres) or custom (give spacing_in).","enum":["19-w-4","15-w-4","custom"],"default":"19-w-4"},"spacing_in":{"type":"number","description":"Bearing bar centre-to-centre spacing in inches. Required when pattern is custom.","x-unit":"in"},"bar_thickness_in":{"type":"number","description":"Bearing bar thickness in inches, for example 0.125 (1/8), 0.1875 (3/16), 0.25 (1/4).","default":0.125,"x-unit":"in"}},"additionalProperties":false},"annotations":{"title":"Accessible grating opening checker (13 mm rule)","readOnlyHint":true},"definitionHash":"7608c2b0df11c05da4ce70a51a05fb98c5cb1de0dcb3f9e6bd2132fa2814178c","schemaStatus":"valid","origin":"official-registry","observedAt":"2026-11-18T05:46:37.653Z","metadataTrust":"untrusted"},{"serverName":"com.thegrateguys/tools","endpointFingerprint":"eb460a635fcdd156e1f4e8aec173cf12565637c41c2e46bc8c82b6e6668edd02","name":"aluminum_stainless_bar_grating_load_calculator","title":null,"description":"Safe load, deflection and the lightest bearing bar for aluminum 6063-T6 and stainless 304, 316, 304L and 316L bar grating at 1-3/16 in bar centres.","inputSchema":{"type":"object","properties":{"material":{"type":"string","description":"Aluminum 6063-T6, stainless 304 or 316, or stainless 304L or 316L.","enum":["al-6063","ss-304-316","ss-304l-316l"],"default":"al-6063"},"span_in":{"type":"number","description":"Clear span in inches, 24 to 108 (the range of the published tables). Give only one of span_in, span_mm. Default 36 in.","x-unit":"in"},"span_mm":{"type":"number","description":"Clear span in millimetres, 610 to 2743.","x-unit":"mm"},"load":{"type":"string","description":"ped = pedestrian, 100 lb/sq ft with a 1/4 in deflection limit; uni = uniform load you give in value; con = concentrated load at mid-span you give in value.","enum":["ped","uni","con"],"default":"ped"},"value":{"type":"number","description":"The load to check when load is uni (lb/sq ft) or con (lb per ft of grating width). Required for uni and con.","x-unit":"lb/sq ft or lb/ft"},"deflection":{"type":"string","description":"Deflection limit in inches, span240 (span / 240), span360 (span / 360) or none (strength only). Ignored for ped.","enum":["0.25","0.125","0.375","span240","span360","none"],"default":"0.25","x-unit":"in"}},"additionalProperties":false},"annotations":{"title":"Aluminum and stainless bar grating load calculator","readOnlyHint":true},"definitionHash":"1fb989ae1051820f73135ad093c72519fd10d30b803ea426699b357a6b959e5b","schemaStatus":"valid","origin":"official-registry","observedAt":"2026-11-18T05:46:37.653Z","metadataTrust":"untrusted"},{"serverName":"com.thegrateguys/tools","endpointFingerprint":"eb460a635fcdd156e1f4e8aec173cf12565637c41c2e46bc8c82b6e6668edd02","name":"bar_grating_load_calculator","title":null,"description":"Finds the lightest welded steel bearing bar (19-W-4 or 15-W-4, smooth or serrated) that carries a clear span and load within a deflection limit.","inputSchema":{"type":"object","properties":{"span_ft":{"type":"number","description":"Clear span in feet, measured in the direction of the bearing bars, 0.5 to 12. Give only one of span_ft, span_in, span_mm. Default 3 ft.","x-unit":"ft"},"span_in":{"type":"number","description":"Clear span in inches (6 to 144).","x-unit":"in"},"span_mm":{"type":"number","description":"Clear span in millimetres (152 to 3658).","x-unit":"mm"},"load":{"type":"string","description":"ped = pedestrian, 100 lb/sq ft with a 1/4 in deflection limit; uni = uniform load you give in value; con = concentrated load at mid-span you give in value.","enum":["ped","uni","con"],"default":"ped"},"value":{"type":"number","description":"The load to check when load is uni (lb/sq ft) or con (lb per ft of grating width). Required for uni and con.","x-unit":"lb/sq ft or lb/ft"},"deflection":{"type":"string","description":"Deflection limit in inches, span240 (span / 240), span360 (span / 360) or none (strength only). Ignored for ped.","enum":["0.25","0.125","0.375","span240","span360","none"],"default":"0.25","x-unit":"in"},"pattern":{"type":"string","description":"19-W-4 (1-3/16 in bar centres), 15-W-4 (15/16 in) or both.","enum":["19-w-4","15-w-4","both"],"default":"19-w-4"},"surface":{"type":"string","description":"Serrated bars are calculated 1/4 in shallower.","enum":["smooth","serrated"],"default":"smooth"},"area_sqft":{"type":"number","description":"Optional total grating area for an approximate total weight.","x-unit":"sq ft"}},"additionalProperties":false},"annotations":{"title":"Steel bar grating load and span calculator","readOnlyHint":true},"definitionHash":"9b39352f58f8c98ddc6c28f1794e8b0431841fb07a9947dfd81bd63ecca4c078","schemaStatus":"valid","origin":"official-registry","observedAt":"2026-11-18T05:46:37.653Z","metadataTrust":"untrusted"},{"serverName":"com.thegrateguys/tools","endpointFingerprint":"eb460a635fcdd156e1f4e8aec173cf12565637c41c2e46bc8c82b6e6668edd02","name":"bar_grating_load_tables","title":null,"description":"Looks up the safe uniform load (U), safe concentrated load (C), deflections and weight for welded steel bar grating by bearing bar size and span.","inputSchema":{"type":"object","properties":{"pattern":{"type":"string","description":"19-W-4 or 15-W-4 pattern.","enum":["19-w-4","15-w-4"],"default":"19-w-4"},"surface":{"type":"string","description":"Serrated bars act 1/4 in shallower.","enum":["smooth","serrated"],"default":"smooth"},"bar":{"type":"string","description":"Optional bearing bar size, depth x thickness in inches, for example 1-1/4x3/16. Leave out for every bar.","enum":["1x1/8","1x3/16","1-1/4x1/8","1-1/4x3/16","1-1/2x1/8","1-1/2x3/16","1-3/4x3/16","2x3/16","2-1/2x3/16"]},"span_ft":{"type":"number","description":"Optional clear span in feet (1 to 12). Tabulated spans are 2 to 8 ft in 6 in steps. Leave out for every tabulated span.","x-unit":"ft"}},"additionalProperties":false},"annotations":{"title":"Bar grating load tables (19-W-4 and 15-W-4)","readOnlyHint":true},"definitionHash":"8bd3396c666abe309b514ce014d4d6a157452110ecb60dfb4e53e15059833529","schemaStatus":"valid","origin":"official-registry","observedAt":"2026-11-18T05:46:37.653Z","metadataTrust":"untrusted"},{"serverName":"com.thegrateguys/tools","endpointFingerprint":"eb460a635fcdd156e1f4e8aec173cf12565637c41c2e46bc8c82b6e6668edd02","name":"bollard_spacing_and_footing_calculator","title":null,"description":"Counts the bollards for a frontage and clear gap, checks the gap against vehicle and wheelchair guidance, gives typical footing and concrete for a standard (not crash rated) steel pipe bollard, and explains crash ratings.","inputSchema":{"type":"object","properties":{"frontage_ft":{"type":"number","description":"Frontage to protect in feet (1 to 1,000). Give only one of frontage_ft, frontage_m. Default 40 ft.","x-unit":"ft"},"frontage_m":{"type":"number","description":"Frontage to protect in metres.","x-unit":"m"},"max_gap_in":{"type":"number","description":"Largest clear gap between bollards you will allow, in inches (12 to 120). Give only one of max_gap_in, max_gap_mm. Default 48 in.","x-unit":"in"},"max_gap_mm":{"type":"number","description":"Largest clear gap in millimetres.","x-unit":"mm"},"pipe":{"type":"string","description":"Nominal pipe size in inches (outside diameter 4.5, 6.625, 8.625, 10.75 in). Footing figures exist for 6 and 8.","enum":["4","6","8","10"],"default":"6"},"ends":{"type":"string","description":"between-fixed-points: the frontage runs between two fixed obstructions such as walls, and the end gaps also count. bollard-at-each-end: the frontage is measured outside edge to outside edge of the end bollards.","enum":["between-fixed-points","bollard-at-each-end"],"default":"between-fixed-points"},"footing_width_in":{"type":"number","description":"Footing width in inches (12 to 48). 18 in square is the figure for a 6 in pipe in the cited guide.","default":18,"x-unit":"in"},"footing_shape":{"type":"string","description":"Footing shape.","enum":["square","round"],"default":"square"},"height_in":{"type":"number","description":"Pipe height above grade in inches (24 to 60). 36 in is the guide figure.","default":36,"x-unit":"in"},"rating":{"type":"string","description":"Optional crash rating to explain.","enum":["M30","M40","M50","P1","P2","P3","P4","K4","K8","K12","PAS68","IWA14"]}},"additionalProperties":false},"annotations":{"title":"Bollard planner: spacing, count and footing","readOnlyHint":true},"definitionHash":"21033b3e428148bb1d08a2a53b7e66a9ba91ca179feb9e2db42c51cf34f9e197","schemaStatus":"valid","origin":"official-registry","observedAt":"2026-11-18T05:46:37.653Z","metadataTrust":"untrusted"},{"serverName":"com.thegrateguys/tools","endpointFingerprint":"eb460a635fcdd156e1f4e8aec173cf12565637c41c2e46bc8c82b6e6668edd02","name":"catch_basin_grate_and_frame_size_finder","title":null,"description":"Names the Ontario Provincial Standard Drawing for a catch basin inlet type, checks the grate bearing on the frame ledge against the NAAMM minimum, gives the range of bearing bar lengths that sit on the ledge, and lists the EN 1433 load class for the traffic.","inputSchema":{"type":"object","properties":{"inlet":{"type":"string","description":"square-flat = OPSD 400.020, General purpose frame and flat grate; square-dished = OPSD 400.010, Dished grate with an overflow path; square-v = OPSD 400.030, V grate; birdcage = OPSD 400.120, Birdcage grate; overflow-perforated = OPSD 400.110, Overflow flat grate with perforated openings; raised-circular = OPSD 400.070, Raised frame with a round grate; curb-inlet = OPSD 400.081, Curb inlet outside the roadway; curb-overflow = OPSD 400.090, Curb inlet overflow.","enum":["square-flat","square-dished","square-v","birdcage","overflow-perforated","raised-circular","curb-inlet","curb-overflow"],"default":"square-flat"},"traffic":{"type":"string","description":"pedestrian = A 15; private-light = B 125; public-light = C 250; road-commercial = D 400; industrial = E 600; extreme = F 900.","enum":["pedestrian","private-light","public-light","road-commercial","industrial","extreme"],"default":"private-light"},"span_mm":{"type":"number","description":"Clear opening between the frame ledges, in the direction the bearing bars will run, 100 to 3,000 mm. Give only one of span_mm, span_in. Default 500 mm.","x-unit":"mm"},"span_in":{"type":"number","description":"The same clear opening in inches.","x-unit":"in"},"seat_mm":{"type":"number","description":"Width of the ledge the grate sits on, each end, in millimetres (0 to 300).","default":40,"x-unit":"mm"},"bar_depth_in":{"type":"number","description":"Depth of the grate bearing bars in inches (0.75 to 6), for example 1.25 or 2.5.","default":1.25,"x-unit":"in"}},"additionalProperties":false},"annotations":{"title":"Catch basin grate and frame finder (OPSD type, bearing check, load class)","readOnlyHint":true},"definitionHash":"2d39068b2926bce8755df49437c912b82d33bd3ef928cc193b381373548316ec","schemaStatus":"valid","origin":"official-registry","observedAt":"2026-11-18T05:46:37.653Z","metadataTrust":"untrusted"},{"serverName":"com.thegrateguys/tools","endpointFingerprint":"eb460a635fcdd156e1f4e8aec173cf12565637c41c2e46bc8c82b6e6668edd02","name":"fence_and_gate_post_spacing_and_weight","title":null,"description":"Post count and spacing for a chain link or ornamental steel fence run, chain link footing depth and gate post size, and the weight and hinge loads of an ornamental steel gate leaf.","inputSchema":{"type":"object","properties":{"panel":{"type":"string","description":"chain-link (line posts 10 ft apart at most) or ornamental steel tubular pickets (8 ft, 96 in on center).","enum":["chain-link","ornamental"],"default":"ornamental"},"run_ft":{"type":"number","description":"Length of the fence run in feet, not counting the gate (3 to 2,000).","default":40,"x-unit":"ft"},"height_ft":{"type":"number","description":"Fence and gate height in feet (3 to 12).","default":6,"x-unit":"ft"},"gate_ft":{"type":"number","description":"Gate opening in feet, 0 for no gate (0 to 24). The gate sits at the end of the run.","default":0,"x-unit":"ft"},"leaves":{"type":"string","description":"Single or double leaf gate.","enum":["1","2"],"default":1},"tube_in":{"type":"number","description":"Ornamental gate frame: square tube outside size in inches.","default":1.5,"x-unit":"in"},"wall_in":{"type":"number","description":"Ornamental gate frame: tube wall in inches (0.12 is about 11 gauge).","default":0.12,"x-unit":"in"},"picket_in":{"type":"number","description":"Ornamental gate: square picket size in inches.","default":0.5,"x-unit":"in"},"gap_in":{"type":"number","description":"Ornamental gate: largest gap between pickets in inches (4 in is the most the maker chart allows).","default":3.5,"x-unit":"in"},"mid_rails":{"type":"number","description":"Ornamental gate: rails between the top and bottom rail.","default":1},"hinge_spacing_in":{"type":"number","description":"Distance between the two hinges in inches. Default: gate height less 24 in.","x-unit":"in"},"post_od_in":{"type":"number","description":"Chain link line post outside diameter in inches, to get the footing diameter.","x-unit":"in"}},"additionalProperties":false},"annotations":{"title":"Fence and gate post spacing, post count and gate weight","readOnlyHint":true},"definitionHash":"07e22cda1d5c39da07021e79f6623be9f1e64dfd87663e390ba7fc88f8d01758","schemaStatus":"valid","origin":"official-registry","observedAt":"2026-11-18T05:46:37.653Z","metadataTrust":"untrusted"},{"serverName":"com.thegrateguys/tools","endpointFingerprint":"eb460a635fcdd156e1f4e8aec173cf12565637c41c2e46bc8c82b6e6668edd02","name":"galvanizing_coating_thickness_calculator","title":null,"description":"Minimum average hot-dip galvanized coating grade by steel category and thickness, in mils, microns and ounces of zinc per square foot, with total zinc for a surface area.","inputSchema":{"type":"object","properties":{"category":{"type":"string","description":"shapes = structural shapes (angles, channels, beams); strip = strip and bar; plate; pipe = pipe and tubing; wire; rebar = reinforcing bar.","enum":["shapes","strip","plate","pipe","wire","rebar"],"default":"shapes"},"thickness_in":{"type":"number","description":"Steel thickness in inches. Give only one of thickness_in, thickness_mm. Default 0.1875 in.","x-unit":"in"},"thickness_mm":{"type":"number","description":"Steel thickness in millimetres.","x-unit":"mm"},"area_sqft":{"type":"number","description":"Optional surface area to be coated, for the minimum zinc weight.","x-unit":"sq ft"}},"additionalProperties":false},"annotations":{"title":"Galvanizing coating thickness calculator (ASTM A123)","readOnlyHint":true},"definitionHash":"7afa5e61806e796874572c1fff2601b0d22797bdb296b178e282c837c651c8b7","schemaStatus":"valid","origin":"official-registry","observedAt":"2026-11-18T05:46:37.653Z","metadataTrust":"untrusted"},{"serverName":"com.thegrateguys/tools","endpointFingerprint":"eb460a635fcdd156e1f4e8aec173cf12565637c41c2e46bc8c82b6e6668edd02","name":"guard_and_railing_code_checker_ontario","title":null,"description":"Whether a guard is required, its minimum height, opening limit, climbing rule and design loads under the Ontario Building Code Part 9 and Part 3 for a described situation.","inputSchema":{"type":"object","properties":{"location":{"type":"string","description":"dwelling = within a dwelling unit; exthouse = exterior serving one dwelling unit; part9 = other Part 9 building; exit3 = required exit in a larger (Part 3) building.","enum":["dwelling","exthouse","part9","exit3"],"default":"part9"},"use":{"type":"string","description":"normal = ordinary guard; equip = access way to an equipment platform where many people are improbable.","enum":["normal","equip"],"default":"normal"},"unit":{"type":"string","description":"Unit of every length below.","enum":["mm","in"],"default":"mm"},"drop":{"type":"number","description":"Drop to the adjacent surface within 1.2 m (4 ft). A guard is required above 600 mm (23.6 in).","default":900,"x-unit":"per the unit parameter"},"height_above_grade":{"type":"number","description":"Walking surface height above grade.","default":900,"x-unit":"per the unit parameter"},"planned_height":{"type":"number","description":"Guard height you plan.","default":1070,"x-unit":"per the unit parameter"},"opening":{"type":"number","description":"Largest opening: the widest sphere that passes through the guard.","default":95,"x-unit":"per the unit parameter"},"stair_triangle":{"type":"number","description":"Optional stair triangle gap, widest sphere.","x-unit":"per the unit parameter"},"industrial":{"type":"boolean","description":"Industrial occupancy.","default":false},"maintenance_only":{"type":"boolean","description":"Access for maintenance only.","default":false},"loading_dock":{"type":"boolean","description":"Loading dock.","default":false}},"additionalProperties":false},"annotations":{"title":"Ontario guard and railing code checker","readOnlyHint":true},"definitionHash":"d946a9294bef37316dc48e114c0611e3c805ed7330ef9612decc36055ded6396","schemaStatus":"valid","origin":"official-registry","observedAt":"2026-11-18T05:46:37.653Z","metadataTrust":"untrusted"},{"serverName":"com.thegrateguys/tools","endpointFingerprint":"eb460a635fcdd156e1f4e8aec173cf12565637c41c2e46bc8c82b6e6668edd02","name":"loading_dock_height_and_leveler_check","title":null,"description":"The grade a dock leveler works at between the lowest and highest truck bed you serve, against the 10% (electric) and 15% (gas or diesel) limits, the shortest standard leveler length that fits, and whether two makers published working ranges cover it.","inputSchema":{"type":"object","properties":{"dock_height_in":{"type":"number","description":"Dock floor height above the driveway in inches (20 to 80). The most common dock height is 48 to 52 in.","default":48,"x-unit":"in"},"bed_low_in":{"type":"number","description":"Lowest truck bed height you serve, in inches (20 to 80). Vehicle beds range from 30 to 62 in.","default":44,"x-unit":"in"},"bed_high_in":{"type":"number","description":"Highest truck bed height you serve, in inches.","default":52,"x-unit":"in"},"leveler_ft":{"type":"string","description":"Leveler length in feet. Standard lengths are 6, 8, 10 and 12 ft.","enum":["6","8","10","12"],"default":8},"equipment":{"type":"string","description":"electric = pallet, skid or electric fork trucks (10% grade limit); combustion = gas or diesel fork trucks (15%).","enum":["electric","combustion"],"default":"electric"}},"additionalProperties":false},"annotations":{"title":"Loading dock height and leveler check","readOnlyHint":true},"definitionHash":"4bf419572556ee4f921f42e758bc27889309e5bcd93a32c810dfb065ba239a5d","schemaStatus":"valid","origin":"official-registry","observedAt":"2026-11-18T05:46:37.653Z","metadataTrust":"untrusted"},{"serverName":"com.thegrateguys/tools","endpointFingerprint":"eb460a635fcdd156e1f4e8aec173cf12565637c41c2e46bc8c82b6e6668edd02","name":"steel_beam_lintel_span_check","title":null,"description":"The steel angle lintel or steel beam that the 2024 Ontario Building Code Part 9 tables list for an opening width in a brick or stone veneer wall or a masonry wall, with the 150 mm bearing rule. Not a stamped design.","inputSchema":{"type":"object","properties":{"opening_mm":{"type":"number","description":"Clear opening width in millimetres (300 to 6,000). Give only one of opening_mm, opening_ft. Default 2,000 mm.","x-unit":"mm"},"opening_ft":{"type":"number","description":"Clear opening width in feet.","x-unit":"ft"},"wall":{"type":"string","description":"veneer-brick-70 = 70 mm brick veneer; veneer-brick-90 = 90 mm brick veneer; veneer-stone-100 = 100 mm stone veneer; solid-brick-100 = masonry wall, 100 mm brick (Table 9.20.5.2.-A, exterior angle); solid-stone-150 = masonry wall, 100 mm brick plus 50 mm stone facing (Table 9.20.5.2.-A, exterior angle).","enum":["veneer-brick-70","veneer-brick-90","veneer-stone-100","solid-brick-100","solid-stone-150"],"default":"veneer-brick-90"},"member":{"type":"string","description":"angle = steel angle lintel; beam = steel beam supporting masonry veneer and a wood stud wall (veneer walls only).","enum":["angle","beam"],"default":"angle"},"bearing_mm":{"type":"number","description":"Optional: the bearing length you have at each end, to check against the 150 mm minimum.","x-unit":"mm"}},"additionalProperties":false},"annotations":{"title":"Steel lintel and beam span check (2024 Ontario Building Code Part 9)","readOnlyHint":true},"definitionHash":"9fa108d1b60098a8c09b7b878534b33c50f7a39741fde80a8ab80fc2e4cc6230","schemaStatus":"valid","origin":"official-registry","observedAt":"2026-11-18T05:46:37.653Z","metadataTrust":"untrusted"},{"serverName":"com.thegrateguys/tools","endpointFingerprint":"eb460a635fcdd156e1f4e8aec173cf12565637c41c2e46bc8c82b6e6668edd02","name":"steel_stair_calculator_ontario","title":null,"description":"Allowed riser counts, riser height, tread run, flights, width, headroom and handrail height for a total rise under Ontario Building Code Part 9.","inputSchema":{"type":"object","properties":{"stair_type":{"type":"string","description":"private = inside or outside a house or single dwelling unit; public = every other stair; service = serves service rooms only (Table 9.8.4.1.).","enum":["private","public","service"],"default":"public"},"location":{"type":"string","description":"dwelling = within a dwelling unit or house; exitres = exit or public stair, residential building; exitother = exit or public stair, other building.","enum":["dwelling","exitres","exitother"],"default":"exitother"},"unit":{"type":"string","description":"Unit of every length below.","enum":["mm","in"],"default":"mm"},"total_rise":{"type":"number","description":"Total rise, finished floor to finished floor. At least 375 mm (14.8 in).","default":2800,"x-unit":"per the unit parameter"},"run":{"type":"number","description":"Tread run you want (nosing to nosing).","default":280,"x-unit":"per the unit parameter"},"width":{"type":"number","description":"Clear stair width.","default":1000,"x-unit":"per the unit parameter"},"headroom":{"type":"number","description":"Clear headroom over the stair.","default":2100,"x-unit":"per the unit parameter"},"handrail":{"type":"number","description":"Handrail height above the nosing line.","default":920,"x-unit":"per the unit parameter"}},"additionalProperties":false},"annotations":{"title":"Ontario steel stair calculator","readOnlyHint":true},"definitionHash":"c06c985e60073cb01333fa1ddb38d86a8a13236ad65e543e0ddf115e814cd3bc","schemaStatus":"valid","origin":"official-registry","observedAt":"2026-11-18T05:46:37.653Z","metadataTrust":"untrusted"},{"serverName":"com.thegrateguys/tools","endpointFingerprint":"eb460a635fcdd156e1f4e8aec173cf12565637c41c2e46bc8c82b6e6668edd02","name":"steel_weight_calculator","title":null,"description":"Theoretical weight of carbon steel plate, flat bar, round bar, square bar, angle, square or rectangular tube and round pipe, in pounds and kilograms.","inputSchema":{"type":"object","properties":{"shape":{"type":"string","description":"plate or sheet, flat bar, round bar, square bar, angle, square or rectangular tube, round pipe or tube.","enum":["plate","flat","round","square","angle","tube","pipe"],"default":"plate"},"unit":{"type":"string","description":"Unit of every size and the length.","enum":["in","mm"],"default":"in"},"width":{"type":"number","description":"Width: plate, flat bar, tube.","x-unit":"per the unit parameter"},"thickness":{"type":"number","description":"Thickness: plate, flat bar, angle.","x-unit":"per the unit parameter"},"diameter":{"type":"number","description":"Diameter: round bar.","x-unit":"per the unit parameter"},"side":{"type":"number","description":"Side: square bar.","x-unit":"per the unit parameter"},"leg_a":{"type":"number","description":"Leg A: angle.","x-unit":"per the unit parameter"},"leg_b":{"type":"number","description":"Leg B: angle.","x-unit":"per the unit parameter"},"height":{"type":"number","description":"Height: rectangular tube.","x-unit":"per the unit parameter"},"wall":{"type":"number","description":"Wall thickness: tube and pipe.","x-unit":"per the unit parameter"},"outside_diameter":{"type":"number","description":"Outside diameter: pipe.","x-unit":"per the unit parameter"},"length":{"type":"number","description":"Length of one piece.","default":12,"x-unit":"per the unit parameter"},"quantity":{"type":"number","description":"Number of pieces.","default":1}},"additionalProperties":false},"annotations":{"title":"Steel weight calculator","readOnlyHint":true},"definitionHash":"679e029e618605df63b31de01b0f3953accdf6329730aba73d26331877ef8eb0","schemaStatus":"valid","origin":"official-registry","observedAt":"2026-11-18T05:46:37.653Z","metadataTrust":"untrusted"},{"serverName":"com.thegrateguys/tools","endpointFingerprint":"eb460a635fcdd156e1f4e8aec173cf12565637c41c2e46bc8c82b6e6668edd02","name":"trench_drain_flow_capacity_calculator","title":null,"description":"The flow a trench drain has to handle from a paved area (rational method with Toronto City rainfall rates from Environment and Climate Change Canada) and the flow the channel carries (Manning), with the narrowest channel that works.","inputSchema":{"type":"object","properties":{"area_m2":{"type":"number","description":"Paved area draining to the trench in square metres (1 to 100,000). Give only one of area_m2, area_sqft. Default 500 m2.","x-unit":"m2"},"area_sqft":{"type":"number","description":"The same area in square feet.","x-unit":"sq ft"},"surface":{"type":"string","description":"asphalt = Asphalt pavement; concrete = Concrete pavement; brick = Brick or interlocking paver; drive-walk = Driveway or walkway; roof = Roof; lawn-heavy-flat = Lawn, heavy soil, flat (2% or less). The top of the range for the surface is used unless c is given.","enum":["asphalt","concrete","brick","drive-walk","roof","lawn-heavy-flat"],"default":"asphalt"},"c":{"type":"number","description":"Optional runoff coefficient C (above 0, up to 1) to use instead of the top of the range for the surface."},"period":{"type":"string","description":"Return period in years.","enum":["2","5","10","25","50","100"],"default":10},"duration":{"type":"string","description":"Storm duration in minutes, taken as the time of concentration.","enum":["5","10","15","30"],"default":10},"width_mm":{"type":"number","description":"Channel internal width in millimetres (50 to 1,000).","default":150,"x-unit":"mm"},"depth_mm":{"type":"number","description":"Water depth at the outlet end in millimetres (30 to 1,000).","default":150,"x-unit":"mm"},"slope_pct":{"type":"number","description":"Channel slope in percent (0.05 to 20).","default":1,"x-unit":"%"},"lining":{"type":"string","description":"concrete-trowel = Concrete, trowel finish; concrete-float = Concrete, float finish; concrete-unfinished = Concrete, unfinished; plastic-smooth = Smooth plastic.","enum":["concrete-trowel","concrete-float","concrete-unfinished","plastic-smooth"],"default":"concrete-trowel"}},"additionalProperties":false},"annotations":{"title":"Trench drain flow and channel capacity calculator","readOnlyHint":true},"definitionHash":"dc57fc9e5a1c707f22c2cbe1162d7c725872d149e5ad43900cc1a14ffdeba66a","schemaStatus":"valid","origin":"official-registry","observedAt":"2026-11-18T05:46:37.653Z","metadataTrust":"untrusted"},{"serverName":"com.thegrateguys/tools","endpointFingerprint":"eb460a635fcdd156e1f4e8aec173cf12565637c41c2e46bc8c82b6e6668edd02","name":"trench_drain_grate_load_class","title":null,"description":"The EN 1433 load class, A 15 to F 900, and its test load in kN for where a trench drain goes and what drives or rolls over it.","inputSchema":{"type":"object","properties":{"application":{"type":"string","description":"footpath = Footpath, patio, pool deck or cycle path; domestic-driveway = Domestic driveway (cars and light vans); private-road = Private road or slow residential lane; public-space = Public space or plaza with light vehicles; car-park = Car park (slow, light vehicles); retail-parking = Supermarket or retail parking lot; petrol-forecourt = Petrol station forecourt (fuel delivery trucks cross it); vans-light-trucks = Vans and light trucks up to 7.5 t; public-road-trucks = Public road, carriageway or commercial driveway with trucks; logistics-bus = Logistics area or bus station; industrial-forklift = Industrial yard or loading dock apron with forklifts; port-airport = Container terminal, port, airport or aircraft apron. If more than one applies, pick the heaviest.","enum":["footpath","domestic-driveway","private-road","public-space","car-park","retail-parking","petrol-forecourt","vans-light-trucks","public-road-trucks","logistics-bus","industrial-forklift","port-airport"],"default":"domestic-driveway"}},"additionalProperties":false},"annotations":{"title":"Trench drain grate load class picker (EN 1433)","readOnlyHint":true},"definitionHash":"986ea1eb84fa5c6c37d82dd12a28f5cb30e105165d50904f365da98dcdd172e7","schemaStatus":"valid","origin":"official-registry","observedAt":"2026-11-18T05:46:37.653Z","metadataTrust":"untrusted"}],"endpoints":[{"endpointFingerprint":"eb460a635fcdd156e1f4e8aec173cf12565637c41c2e46bc8c82b6e6668edd02","protocol":"streamable-http","status":"indexed","toolCount":15,"observedAt":"2026-11-18T05:46:37.653Z"}],"authentication":"unknown"},"connectionConfigurations":{"status":"ready","authentication":"not embedded","clients":{"Claude Desktop":{"mcpServers":{"com.thegrateguys/tools":{"url":"https://thegrateguys.com/mcp"}}},"Cursor":{"mcpServers":{"com.thegrateguys/tools":{"url":"https://thegrateguys.com/mcp"}}},"VS Code":{"servers":{"com.thegrateguys/tools":{"type":"http","url":"https://thegrateguys.com/mcp"}}}}},"resourceType":"mcp-server","callable":true,"runtime":{"callable":true,"protocols":["mcp"]},"interfaces":[{"protocol":"mcp","transport":"streamable-http","url":"https://thegrateguys.com/mcp"}],"profile":{"apiVersion":"1","schemaVersion":"1","id":"mcp-server:com.thegrateguys%2Ftools","resourceType":"mcp-server","canonicalUrl":"https://www.agentsjunction.com/api/v1/servers/com.thegrateguys%2Ftools","name":"com.thegrateguys/tools","description":"Planning calculators for metal grating, drainage covers and fabrication.","interfaces":[{"protocol":"mcp","transport":"streamable-http","url":"https://thegrateguys.com/mcp"}],"capabilities":[],"identity":{"source":"official-registry","websiteUrl":null,"repositoryUrl":null,"version":"1.0.0"},"verification":{"state":"official","confidence":100},"operations":{"resourceType":"mcp-server","name":"com.thegrateguys/tools","status":"online","lastCheckedAt":"2026-11-20T09:17:49.390Z","lastSuccessfulCheck":"2026-11-20T09:17:49.390Z","latencyMs":43,"consecutiveFailures":0,"isStale":false,"checks":{"endpointReachable":true,"protocolValid":true,"agentCardValid":null,"mcpHandshakeValid":true},"lastSeen":null,"lastSuccessfulInteraction":null,"lastHealthCheck":"2026-11-20T09:17:49.390Z","source":{"type":"health-check","url":null},"observedAt":"2026-11-20T09:17:49.390Z"},"security":null,"timestamps":{"createdAt":"2026-11-16T21:56:17.668Z","updatedAt":"2026-11-16T21:56:17.668Z","observedAt":"2026-11-20T09:17:49.390Z"},"compatibility":{"serverVersion":"1.0.0","protocolVersions":[{"protocol":"mcp","version":null}]}}}}