{"data":{"name":"be.planelec/calculators","title":"PlanElec Calculators","description":"Free AREI cable sizing, Synergrid C10/26 inverter check, LED strip calculator. No account.","version":"0.2.0","websiteUrl":"https://planelec.be/integrations/ai-assistants","repositoryUrl":null,"remotes":[{"type":"streamable-http","url":"https://planelec.be/mcp/public"}],"packages":[],"status":"active","isLatest":true,"publishedAt":"2026-11-05T21:27:19.710Z","updatedAt":"2026-11-05T21:27:19.710Z","source":"official-registry","verification":"official","confidence":100,"stars":null,"sources":[{"source":"official-registry","sourceId":"be.planelec/calculators","verification":"official","confidence":100,"stars":null,"updatedAt":"2026-11-05T21:27:19.710Z","title":"PlanElec Calculators","description":"Free AREI cable sizing, Synergrid C10/26 inverter check, LED strip calculator. No account.","websiteUrl":"https://planelec.be/integrations/ai-assistants","repositoryUrl":null}],"toolIndex":{"tools":[{"serverName":"be.planelec/calculators","endpointFingerprint":"61716b4c1e660fa11804cae6a6c9485c7d365717b970faa97d4840d42bd66b31","name":"calculate_led_strip","title":"Calculate an LED strip: current, power supply, feed points","description":"Calculates power, current (total and per channel), required feed points, power-supply size and the extra-low-voltage feed cable for an analogue LED strip (5/12/24/48 V DC; single colour, CCT, RGB, RGBW, RGB+CCT). Provide the strip length in metres and either a preset or the datasheet values (voltage, colour channels, watts per metre at full load). Optional: cut unit, maximum length per feed, number of feeds, power-supply reserve, feed-cable length, material and cross-section, and voltage-drop limit. Planning values from datasheet data, not a manufacturer guarantee; current-carrying capacity, heat and AREI/RGIE rules for SELV, bathrooms and outdoor areas are not checked. The response includes a shareable link that opens the calculation on planelec.be.","inputSchema":{"type":"object","properties":{"preset":{"description":"Typical strip class as starting values; explicit fields override it.","type":"string","enum":["12v_mono_4_8","24v_mono_9_6","24v_mono_14_4","24v_cob_10","24v_cct_19_2","24v_rgb_14_4","24v_rgbw_19_2","48v_mono_10"]},"voltage":{"description":"Strip nominal voltage in V DC. Default: 24.","type":"number","enum":[5,12,24,48]},"colorMode":{"description":"Colour channels: mono, cct, rgb, rgbw or rgbcct. Default: mono.","type":"string","enum":["mono","cct","rgb","rgbw","rgbcct"]},"powerPerMeterW":{"description":"Power per metre in W with all channels at full brightness. Default: 14.4.","type":"number","exclusiveMinimum":0,"maximum":200},"lengthM":{"type":"number","exclusiveMinimum":0,"maximum":500,"description":"Strip length in metres."},"cutUnitMm":{"description":"Cut unit in mm; the length is rounded down to it.","type":"number","exclusiveMinimum":0,"maximum":1000},"maxRunM":{"description":"Manufacturer's maximum strip length per feed in m. Default: 5.","type":"number","exclusiveMinimum":0,"maximum":100},"feeds":{"description":"Planned number of feed points; defaults to the minimum.","type":"integer","minimum":1,"maximum":100},"psuReservePercent":{"description":"Power-supply reserve in percent. Default: 20.","type":"number","minimum":0,"maximum":100},"feedLengthM":{"description":"One-way feed-cable length from power supply to strip in m. Default: 5.","type":"number","exclusiveMinimum":0,"maximum":1000},"feedMaterial":{"description":"Feed-cable conductor material. Default: CU.","type":"string","enum":["CU","AL"]},"feedCrossSectionMm2":{"description":"Planned feed-cable cross-section in mm²; omit for a recommendation only.","type":"number","enum":[0.5,0.75,1,1.5,2.5,4,6,10]},"maxFeedDropPercent":{"description":"Feed-cable voltage-drop limit in percent (planning assumption). Default: 3.","type":"number","exclusiveMinimum":0,"maximum":20},"locale":{"description":"Language of source titles and links (nl, fr, de, en). Defaults to the server setting.","type":"string","enum":["nl","fr","de","en"]}},"required":["lengthM"],"$schema":"http://json-schema.org/draft-07/schema#"},"annotations":{"readOnlyHint":true,"idempotentHint":true,"openWorldHint":true},"definitionHash":"43e7286ed46571d937cf0aa8de86934381f9e68f00e06e43cda719957409e94e","schemaStatus":"valid","origin":"official-registry","observedAt":"2026-11-18T12:46:08.793Z","metadataTrust":"untrusted"},{"serverName":"be.planelec/calculators","endpointFingerprint":"61716b4c1e660fa11804cae6a6c9485c7d365717b970faa97d4840d42bd66b31","name":"check_inverter_c10_26","title":"Check an inverter against Synergrid C10/26","description":"Checks whether a PV inverter, battery inverter or other power-generating unit (PGU) is on the Synergrid C10/26 list of devices homologated for connection to the Belgian grid. Returns the outcome (found, found_with_limitations, expired, not_found, brand), matching devices with homologation dates, limitations and firmware versions, and homologated alternatives when nothing matches. Where available, each match also carries a separate \"datasheet\" object with manufacturer datasheet values (DC voltage, MPPT data, links, source URLs, status, last verified date); these are NOT checked by Synergrid and are not part of the approval. Search by brand and model, for example \"Huawei SUN2000-10KTL\".","inputSchema":{"type":"object","properties":{"query":{"type":"string","description":"Brand and/or model, 2–80 characters."},"smaxVa":{"description":"Optional: apparent power in VA, improves alternative suggestions.","type":"number"},"phases":{"description":"Optional: 1 or 3 phases, improves alternative suggestions.","type":"number","enum":[1,3]},"locale":{"description":"Language of source titles and links (nl, fr, de, en). Defaults to the server setting.","type":"string","enum":["nl","fr","de","en"]}},"required":["query"],"$schema":"http://json-schema.org/draft-07/schema#"},"annotations":{"readOnlyHint":true,"idempotentHint":true,"openWorldHint":true},"definitionHash":"b20499339bbfb288a79d6e61801cc7edf91d13425bc5339b664d89dcef009995","schemaStatus":"valid","origin":"official-registry","observedAt":"2026-11-18T12:46:08.793Z","metadataTrust":"untrusted"},{"serverName":"be.planelec/calculators","endpointFingerprint":"61716b4c1e660fa11804cae6a6c9485c7d365717b970faa97d4840d42bd66b31","name":"get_inverter_datasheet","title":"Get inverter datasheet data","description":"Returns manufacturer datasheet data for an inverter from the Synergrid C10/26 list: maximum DC voltage, MPPT count and range, current limits per MPPT, start voltage, maximum PV power, battery capability, optimizer architecture, links to the datasheet and installation manual, the product photo URL, source URL and page per value, status (verified = stated in the datasheet, secondary = unconfirmed) and the date last verified. These are manufacturer statements and are NOT part of the Synergrid approval; use check_inverter_c10_26 for the approval status. Look up by Synergrid reference (GLV…) or by brand and model.","inputSchema":{"type":"object","properties":{"reference":{"description":"Synergrid reference, e.g. GLV073-06-0020. Alternative to brand and model.","type":"string"},"brand":{"description":"Brand, e.g. Huawei. Use together with model.","type":"string"},"model":{"description":"Model designation, e.g. SUN2000-5KTL-M1. Use together with brand.","type":"string"},"locale":{"description":"Language of source titles and links (nl, fr, de, en). Defaults to the server setting.","type":"string","enum":["nl","fr","de","en"]}},"$schema":"http://json-schema.org/draft-07/schema#"},"annotations":{"readOnlyHint":true,"idempotentHint":true,"openWorldHint":true},"definitionHash":"1848ac655ac2f45c509450a6071c9dc2a32fa9243ead2a0d456fe89164a82e56","schemaStatus":"valid","origin":"official-registry","observedAt":"2026-11-18T12:46:08.793Z","metadataTrust":"untrusted"},{"serverName":"be.planelec/calculators","endpointFingerprint":"61716b4c1e660fa11804cae6a6c9485c7d365717b970faa97d4840d42bd66b31","name":"get_regelwerk_article","title":"Read an AREI/RGIE article","description":"Returns the text of one article of Book 1 of the Belgian AREI/RGIE by its number (for example 4.2.4.3 or \"AREI 7.1.4.3\"), in the language of the text (Dutch, French or German; English uses the German text), with the edition, change notices of amending decrees, the titles of its sub-articles and a link to the article in the PlanElec reader. Cite the article number and edition when you pass the content on. Use search_regelwerk to find the number.","inputSchema":{"type":"object","properties":{"article":{"type":"string","description":"Article number such as 4.2.4.3; a prefix such as \"AREI\" or \"RGIE\" is accepted."},"version":{"description":"Optional edition, e.g. v06 or v07. Default: the edition in force today (v06 until 31/10/2026, v07 from 01/11/2026).","type":"string","pattern":"^v\\d{2}$"},"locale":{"description":"Language of source titles and links (nl, fr, de, en). Defaults to the server setting.","type":"string","enum":["nl","fr","de","en"]}},"required":["article"],"$schema":"http://json-schema.org/draft-07/schema#"},"annotations":{"readOnlyHint":true,"idempotentHint":true,"openWorldHint":false},"definitionHash":"7be0a0f3fd8f8629607fee88384d354163eec6e46812ea684fd16d867d3936e1","schemaStatus":"valid","origin":"official-registry","observedAt":"2026-11-18T12:46:08.793Z","metadataTrust":"untrusted"},{"serverName":"be.planelec/calculators","endpointFingerprint":"61716b4c1e660fa11804cae6a6c9485c7d365717b970faa97d4840d42bd66b31","name":"search_help_guides","title":"Search the PlanElec help center","description":"Searches the PlanElec guides about getting started, automatic planning, document exports, AREI self-check coverage, floor plan import, symbols and circuits in the visitor’s current language. Returns up to five guides with title, summary, category and a link to the full article; the article text itself is not returned.","inputSchema":{"type":"object","properties":{"query":{"description":"Keywords matched against title, summary and tags. Empty lists all guides.","type":"string"},"locale":{"description":"Language of source titles and links (nl, fr, de, en). Defaults to the server setting.","type":"string","enum":["nl","fr","de","en"]}},"$schema":"http://json-schema.org/draft-07/schema#"},"annotations":{"readOnlyHint":true,"idempotentHint":true,"openWorldHint":true},"definitionHash":"8ad6dd4ff59edf3f9cb4276305b7a36ddfdb141e6bc0e0e351123c11a247b54f","schemaStatus":"valid","origin":"official-registry","observedAt":"2026-11-18T12:46:08.793Z","metadataTrust":"untrusted"},{"serverName":"be.planelec/calculators","endpointFingerprint":"61716b4c1e660fa11804cae6a6c9485c7d365717b970faa97d4840d42bd66b31","name":"search_regelwerk","title":"Search the Belgian AREI/RGIE regulations","description":"Searches Book 1 of the Belgian AREI/RGIE (Royal Decree on electrical installations) in the language of the text: Dutch, French or German; English uses the German text. Returns up to ten articles with number, title, an excerpt, the edition in force today and a link to the article in the PlanElec reader; the full article text is not returned, use get_regelwerk_article for it. Search by keywords or by article number such as 4.2.4.3. Results are planning aids, not an official inspection.","inputSchema":{"type":"object","properties":{"query":{"type":"string","description":"Keywords or an article number such as 5.2.2.1 or 4.2.4.3, 2–120 characters."},"version":{"description":"Optional edition, e.g. v06 or v07. Default: the edition in force today (v06 until 31/10/2026, v07 from 01/11/2026).","type":"string","pattern":"^v\\d{2}$"},"limit":{"description":"Maximum number of articles, 1–10. Default: 5.","type":"integer","minimum":1,"maximum":10},"locale":{"description":"Language of source titles and links (nl, fr, de, en). Defaults to the server setting.","type":"string","enum":["nl","fr","de","en"]}},"required":["query"],"$schema":"http://json-schema.org/draft-07/schema#"},"annotations":{"readOnlyHint":true,"idempotentHint":true,"openWorldHint":false},"definitionHash":"a341c3b04f175b089e7d48d13252e3704802c98a82a83235755bacd87c306d6b","schemaStatus":"valid","origin":"official-registry","observedAt":"2026-11-18T12:46:08.793Z","metadataTrust":"untrusted"},{"serverName":"be.planelec/calculators","endpointFingerprint":"61716b4c1e660fa11804cae6a6c9485c7d365717b970faa97d4840d42bd66b31","name":"size_cable_arei","title":"Size a cable per AREI/RGIE","description":"Calculates the required copper or aluminium cable cross-section for a residential circuit under the Belgian AREI/RGIE: design current, voltage drop per cross-section, protection check against the breaker rating and the recommended cross-section. Provide the load (A, W, kW or kVA), one-way cable length in metres, the network (1x230V, 3x230V, 3x400V) and the breaker rating; other fields use the defaults for a typical socket circuit. The response includes a shareable link that opens the same calculation on planelec.be.","inputSchema":{"type":"object","properties":{"mode":{"description":"‘plan’ recommends a cross-section; ‘check’ evaluates selectedCrossSectionMm2.","type":"string","enum":["check","plan"]},"network":{"description":"Supply network. Default: 1x230V.","type":"string","enum":["1x230V","3x230V","3x400V"]},"circuitPhases":{"description":"Circuit type; three-phase requires a 3x network.","type":"string","enum":["single","three"]},"loadValue":{"description":"Load magnitude in loadUnit. Default: 16.","type":"number","exclusiveMinimum":0},"loadUnit":{"description":"Unit of loadValue. Default: A.","type":"string","enum":["A","W","kW","kVA"]},"lengthM":{"description":"One-way cable length in metres. Default: 30.","type":"number","exclusiveMinimum":0},"material":{"description":"Conductor material. Default: CU.","type":"string","enum":["CU","AL"]},"circuitKind":{"description":"‘lighting’ applies the 3% voltage-drop limit, ‘other’ 5%.","type":"string","enum":["lighting","other"]},"breakerAmps":{"description":"Circuit-breaker rating in A. Default: 16.","type":"number","exclusiveMinimum":0},"cosPhi":{"description":"Power factor 0–1. Default: 0.95.","type":"number","exclusiveMinimum":0,"maximum":1},"selectedCrossSectionMm2":{"description":"Cross-section to evaluate in ‘check’ mode.","type":"number","enum":[1.5,2.5,4,6,10,16,25,35,50]},"nominalVoltage":{"description":"Optional override of the nominal voltage (≤ 1000 V).","type":"number","exclusiveMinimum":0,"maximum":1000},"locale":{"description":"Language of source titles and links (nl, fr, de, en). Defaults to the server setting.","type":"string","enum":["nl","fr","de","en"]}},"$schema":"http://json-schema.org/draft-07/schema#"},"annotations":{"readOnlyHint":true,"idempotentHint":true,"openWorldHint":true},"definitionHash":"5e7f92d78b03e77d1b1fd0910fe3b18aac2753292bfb5c917ee435abe8523f8b","schemaStatus":"valid","origin":"official-registry","observedAt":"2026-11-18T12:46:08.793Z","metadataTrust":"untrusted"},{"serverName":"be.planelec/calculators","endpointFingerprint":"61716b4c1e660fa11804cae6a6c9485c7d365717b970faa97d4840d42bd66b31","name":"suggest_inverter_c10_26","title":"Suggest brands or models from the Synergrid C10/26 list","description":"Typeahead for the Synergrid C10/26 list: given a partial brand or model name, returns matching brands with device counts or, once a brand is recognised, its homologated models. Use this to resolve an ambiguous device name before calling check_inverter_c10_26.","inputSchema":{"type":"object","properties":{"query":{"type":"string","description":"Partial brand or model name, 1–80 characters."},"locale":{"description":"Language of source titles and links (nl, fr, de, en). Defaults to the server setting.","type":"string","enum":["nl","fr","de","en"]}},"required":["query"],"$schema":"http://json-schema.org/draft-07/schema#"},"annotations":{"readOnlyHint":true,"idempotentHint":true,"openWorldHint":true},"definitionHash":"868406ac97b2365a0d670978749bf41b128a9456f7bfa3df8fac1f8d9f5b5487","schemaStatus":"valid","origin":"official-registry","observedAt":"2026-11-18T12:46:08.793Z","metadataTrust":"untrusted"}],"endpoints":[{"endpointFingerprint":"61716b4c1e660fa11804cae6a6c9485c7d365717b970faa97d4840d42bd66b31","protocol":"streamable-http","status":"indexed","toolCount":8,"observedAt":"2026-11-18T12:46:08.793Z"}],"authentication":"unknown"},"connectionConfigurations":{"status":"ready","authentication":"not embedded","clients":{"Claude Desktop":{"mcpServers":{"be.planelec/calculators":{"url":"https://planelec.be/mcp/public"}}},"Cursor":{"mcpServers":{"be.planelec/calculators":{"url":"https://planelec.be/mcp/public"}}},"VS Code":{"servers":{"be.planelec/calculators":{"type":"http","url":"https://planelec.be/mcp/public"}}}}},"resourceType":"mcp-server","callable":true,"runtime":{"callable":true,"protocols":["mcp"]},"interfaces":[{"protocol":"mcp","transport":"streamable-http","url":"https://planelec.be/mcp/public"}],"profile":{"apiVersion":"1","schemaVersion":"1","id":"mcp-server:be.planelec%2Fcalculators","resourceType":"mcp-server","canonicalUrl":"https://www.agentsjunction.com/api/v1/servers/be.planelec%2Fcalculators","name":"be.planelec/calculators","description":"Free AREI cable sizing, Synergrid C10/26 inverter check, LED strip calculator. No account.","interfaces":[{"protocol":"mcp","transport":"streamable-http","url":"https://planelec.be/mcp/public"}],"capabilities":[],"identity":{"source":"official-registry","websiteUrl":"https://planelec.be/integrations/ai-assistants","repositoryUrl":null,"version":"0.2.0"},"verification":{"state":"official","confidence":100},"operations":{"resourceType":"mcp-server","name":"be.planelec/calculators","status":"online","lastCheckedAt":"2026-11-20T06:16:49.855Z","lastSuccessfulCheck":"2026-11-20T06:16:49.855Z","latencyMs":759,"consecutiveFailures":0,"isStale":false,"checks":{"endpointReachable":true,"protocolValid":true,"agentCardValid":null,"mcpHandshakeValid":true},"lastSeen":null,"lastSuccessfulInteraction":null,"lastHealthCheck":"2026-11-20T06:16:49.855Z","source":{"type":"health-check","url":null},"observedAt":"2026-11-20T06:16:49.855Z"},"security":null,"timestamps":{"createdAt":"2026-11-05T21:27:19.710Z","updatedAt":"2026-11-05T21:27:19.710Z","observedAt":"2026-11-20T06:16:49.855Z"},"compatibility":{"serverVersion":"0.2.0","protocolVersions":[{"protocol":"mcp","version":null}]}}}}